Chapter 3 Controller LED Diagnostics 85
For controllers in the SMT3 series, you can use the Unit Type
command or the Unit Type Verify command to obtain the result of the
self-test. You can interpret the result using the self-test bit described
in Table 14.
Table 14. LED Diagnostic Codes for SMT3 Series of Controllers
LED Flashes
(per 10 seconds)
Self-Test Bit
Verify Commands)
Error Description
1 0 Reserved.
2 1 ROM error. Firmware checksum
verification error.
3 2 PWM error. Unable to establish PWM
operating range at power-up.
Nonrecoverable error.
4 3 NOVRAM error. The operating
parameters in the controller NOVRAM
are invalid. Using defaults.
5 4 HDW error. The controller hardware
failed (unable to initialize or configure
gate array). Nonrecoverable error.
6 5 Reserved.
76
Cable NOVRAM error
1
. The
linearization data in the cable NOVRAM
is invalid.
8 7 NOVRAM2 error. The linearization data
in the controller NOVRAM is invalid.
1.The cable NOVRAM error will flash the LED until the controller receives the
first valid command from the host.